Inner membrane · gas retention
Inner membrane option A
- Mass per unit area
- 1200 g/m² ±5%
- Tensile strength (warp / weft)
- ≥5800 / ≥5400 N/5 cm
- Methane permeability
- <500 cm³/(m²·d·bar); temperature not stated
View full data and applicability notes
Published PDF page preview
This is the corresponding page of the published Chinese / English PDF. Open the page to view and zoom the PDF.

View selectable English data and notes
On narrow screens, scroll the table horizontally to see all columns.
| Property | Source value | Method or standard in source |
|---|---|---|
| Base fabric | 100% polyester | Supplier datasheet |
| Coating | PVC | Supplier datasheet |
| Surface finish | High-gloss acrylic finish | Supplier datasheet |
| Mass per unit area | 1200 g/m² ±5% | DIN EN ISO 2286-2 |
| Nominal thickness | Not stated; not inferred | Supplier datasheet |
| Tensile strength (warp / weft) | ≥5800 / ≥5400 N/5 cm | DIN EN ISO 1421-1 |
| Tear resistance (warp / weft) | ≥900 / ≥800 N | DIN 53363 |
| Coating adhesion | ≥110 N/5 cm | DIN EN ISO 2411 · HF method |
| Cold resistance | -30 °C | DIN EN 1876-1 |
| Heat resistance | +70 °C | Supplier method |
| Flex resistance | At least 100,000 bends | DIN 53359 A |
| Methane permeability | <500 cm³/(m²·d·bar); temperature not stated | DIN 53380 Part 2 |
| Fire classification reference | DIN 4102 B1 | DIN 4102 B1 |
- The source includes minimum values and tolerances, not independent test results for every batch.
- Preliminary technical data support selection. The fire classification is a datasheet reference; verify the applicable specimen, test conditions and supply batch for the project.
- Method designations are retained as stated; standard editions have not been silently updated.
Source date: